5. Allowing the dryer to operate for two complete cycles ensures that the probe will not
be exposed to high humidity and damaging liquid water. This is especially important
when dryer has been stored or sitting idle for several months.
6. After this period, slowly open the DDS sample valve so that a small flow of air
passes across the probe (approximately 2 to 3 SCFH). This valve should be open at
all times when dryer is in operation.
7. Now turn the auto/manual selector switch to the “auto” position. The DDS
operational light will come on to provide indication that the Dewpoint Demand
System has been activated.
NOTE
IT IS RECOMMENDED THAT THE DRYER BE OPERATED IN THE MANUAL
MODE FOR A PERIOD OF 4 TO 6 MONTHS WHILE DESICCANT AGING
OCCURS.
2. Failure to Shift Alarm (FTSA)
A. The Failure to Shift Alarm monitors tower shifting and energize an alarm light on the
front panel of the control box should the regenerative dryer fail to cycle.
B. Should dryer fail to cycle because of malfunction of a system component the FTSA light
will be energized. Should FTSA alarm light be observed, refer to “Troubleshooting
Guide” and reset the alarm.
3. High Humidity Alarm (HHA)
A. The High Humidity Alarm monitors the outlet moisture condition and energizes an alarm
light on the front panel of the control box should the regenerative dryer fail to provide
proper dewpoint performance.
B. Should dryer dewpoint elevate because of malfunction of a system component, overflow
condition, oil contamination, or desiccant attrition, the HHA light will be energized.
Should alarm light be observed, refer to “Troubleshooting Guide”.